Description: It's recommended you install new consumable rollers every 350,000 scans. Depending on the condition of the documents you scan, you might think about replacing the rollers even earlier.
Scanner Version: KV-s5055c
You will need: Panasonic KV-SS039 roller exchange kit
Procedure:
1. Turn the unit off.
2. Pull the ADF door release (1) towards you, and open the ADF door (2).
3. Move the lever (1) of the paper feed roller module in the order indicated by the arrow (1,2), and then pull out the module towards you (3).
4. Take out the new paper feed roller module in the "roller exchange kit (KV-SS039).
5. Install the new paper feed roller module.
- With the lever (1) of the paper feed roller module lowered, insert both protrusions (2) into the grooves (3), and then slowly raise the lever in the direction indicated by the arrow until it clicks into place.
6. Pull towards you and remove the double feed prevention roller cover by using the indent (1).
7. While pulling the tab (1) in the direction indicated by the arrow, lift the double feed prevention roller (2)
8. Take out the new double feed prevention roller in the "Roller exchange kit (KV-SS039)"
9. Install the new double feed prevention roller.
- Align the shaft that is shaped as indicated by (1) with the notch in the roller mount (2), and then insert the shaft in the notch. Push the shaft on the opposite side (3) until it clicks into place.
Notice:
After you install the double feed prevention roller, make sure that the shaft is inserted into the tab, and that the shaft will not rotate or move. If the roller is not installed correctly, it may cause double feeding or a paper jam.
10. Insert the protrusion (1) of the double feed prevention roller cover into the hole on the main unit, and then push in the part of the roller cover indicated by (2) in the direction indicated by the arrow until it clicks into place.
Notice: Make sure that the double feed prevention roller cover does not stick up. If the double feed prevention roller cover is closed incompletely, damage or paper jams can occur.
11. Close the ADF door. (push both sides of the ADF door down slowly until it clicks into place.
12. Turn on the scanner.
13. Reset the roller replacing counter in user utility to 0.
- Start user utility, and in the window, click the [clear counter] button for *after replace roller" to reset the counter to 0.
- For details, refer to the user utility help.